<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-03 16-31-03
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.40 MHz 4/5, 52 dBuV YLE YKSI
Pilot RDS Phase Difference
5.9 kHz -88 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
6 kHz 7 kHz 5540 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-3,9 dBr -1,27 dBr 0,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLE YKSI" 6201 14 (Classics) 0 1 1 1 16:31, 3.02.2025
RT
"Ronell: Willow weep for me (Chanticleer/Joseph Jennings). "
AF EON
87.6, 88.6, 89.0, 89.2, 90.4, 92.3, 104.4, 106.5 MHz 6903, 6205, 6202, 6207
FM Scope Max at: 7 kHz MIN: 6 kHz % above 76 kHz: 0,0000 Acquired: 2025/02/03 16.29.59 Total samples: 5540 Equivalent time: 0:04:37 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 0,0 dBr MIN: -3,9 dBr AVE: -1,27 dBr % above 12,2 dBr: 0,0 Last value: -1,2 dBr (2025/02/03 16.29.59) 16.16 16.18 16.20 16.22 16.24 16.26 16.28 -4 -3 -2 -1 0 1 Pm [dBr]